Boiler KPm-3,2

12 000 000 UAH without VAT
Characteristics
  • Nominal steam productivity 3,2 t/h
  • Control range for boiler thermal power 50-100%
  • Efficiency factor, min 85%
  • Exit gas temperature 200 °С
  • Operating pressure of the coolant 14 bar
  • Sound level, max 80 dB
  • Term of the continuous boiler house operation min 8000 h/year
  • Operational service life 20 years
  • Type Fire-tube

Steam boiler plants of KPm series, working with solid fuel, have high automation and good quality of the solid fuel burning process, using the best monitoring devices and control systems.

The use of raw materials as fuel, which does not require additional economic costs for drying and processing, makes these boilers more economical and attractive to consumers.

The use of a complex of systems for storing and fuel supply, ash and slag removing from the furnace and from boiler, ensures high autonomy in the operation of these units.

Steam boilers of this series can be manufactured in fire-tube and water fire-tube versions, and they are equipped with water pre-heating devices (economizers) and flue gas cleaning systems.

The boilers can be used both for: heating and hot water supply systems, and on purpose to support technological processes in different industries, with a working steam pressure of up to 14 Bars.

Fire-tube steam boilers.

Fire-tube steam boilers are designed as a non-cooled, heat-insulated furnace with a movable inclined grate and a fire-tube steam generator.

Fuel is supplied to the furnace by a screw conveyor on command from the boiler operation control system.

The movement of the inclined grate is ensured by hydraulic cylinders.

Ash and slag removal from the furnace is designed as dry, by means of a screw conveyor.

The frequency and duration of operation of the grate and ash removal conveyor is determined by the boiler operation control system, depending on its operating mode.

The fire-tube steam generator is equipped with a device for automatically cleaning of the heat-exchanger pipes with compressed air.

Control of steam boiler operating parameters, coolant level, pressure and steam temperature is set and regulated by the control system.

Delivery set of boiler equipment

1. Blocks of KRIGER KPm steam boilers - consisting of a lined furnace with an inclined grate, a main heat exchanger, an economizer heat exchanger, connecting gas ducts and service platforms and ladders;
For each boiler:
2. A fuel supply device with a boiler bunker equipped with an automated level maintenance system, a sluice gate and fire extinguishing system;
3. Multicyclone filter with hermetic sluice dispenser;
4. Automated ash removal system from the furnace, heat exchanger, multicyclone and economizer into sealed mobile containers;
5. System of pneumatic cleaning of heat exchangers of the boiler and economizer;
6. Circulation and recirculation smoke extractors with frequency control;
7. Set of blower fans with frequency control;
8. A set of pipelines and shut-off and regulating fittings within the boiler;
9. Boiler feed pump station;
10. Automatic continuous purging system with real-time salinity controller;
11.  Hydraulic stations and hydraulic cylinders for the drive of the inclined grating, complete with fittings and hydraulic hoses;
12. The system of automatic control and management of the operation of the installation;
13. Documentation (certificates of conformity, boiler passport, operating instructions, list of equipment, service log, tasks for the development of foundations and connection of communications);